B3806
B3806 05
Stalk Switch Flash to Pass Circuit, Open/Short to B+
Fault symptom
- Main beam flash not working.
On-board diagnosis
Type of diagnosis:
- Continuous
Enable criteria:
- Ignition ON.
- The main beams should be on.
Fault criteria:
- The control module detects that the main beam switch is closed but the main beam flash switch is open.
System reaction to a fault:
- None
Diagnostic help
Diagnosis regards:
- Electrical fault in connecting leads or component.
Functions in the diagnostic tool related to the fault:
Test value:
- Stalk Switch Flash to Pass
(See also description of readings/activations in diagnostic tool)