Expansion Valve: Service and Repair
Expansion Valve
To remove
1. Drain the refrigerant from the A/C system.
2. Detach the A/C pipes from the expansion valve, 1 bolt in centre of valve.
Plug the openings and move the pipes to one side.
3. Remove the expansion valve, 2 countersunk hexagonal socket screws.
IMPORTANT: Be careful not to contaminate the new expansion valve.
1. Replace and lubricate the O-rings with synthetic vaseline, part no. 30 15 286. Fit the O-rings on the pipes from the evaporator.
2. Press the expansion valve onto the A/C pipes to the evaporator and screw it on.
Tightening torque: 5 Nm (4 lbf ft)
3. Remove the plugs. Replace and lubricate the O-rings on the pipes from the compressor and condenser with synthetic vaseline, part no. 30 15 286.
4. Insert the A/C pipes into the expansion valve.
5. Fit the PAD connection (washer) at the valve and screw it on.
Tightening torque: 8 Nm (5 lbf ft)
6. Evacuate the A/C system and fill with R134a refrigerant.