FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Suspension - Front Suspension Knocking/Banging Noises

TECHNICAL SERVICE BULLETIN

Bulletin Nbr: 731-2643 utg.2

Date:...........April 2008

Market: all

Noise in the MacPherson strut

Cars affected
Saab 9-3 4D/5D within Vehicle Identification Number range 31000001 - 71004117
Saab 9-3 CV within Vehicle Identification Number range 46000001 - 76002069

Background

Water may enter the thrust bearing and cause corrosion.

A new, improved sealed thrust bearing has been produced. Water protection according to TSB 731-2643 edition 1 must not be mounted on the new thrust bearing.

In the case of customer complaint, the following procedure must be carried out.

Symptom description

Knocking noise while turning the steering wheel, or banging noise when driving on uneven roads.

Parts required

11 900 364 Screw (3 per MacPherson strut)
13 270 705 Thrust bearing

Procedure

1. Remove the MacPherson strut, in accordance with WIS - Suspension, wheels - Front suspension - Adjustment/Replacement.

2. Dismantle the MacPherson strut, in accordance with WIS - Suspension, wheels - Front suspension - Adjustment/Replacement.

3. Thrust bearing replacement.

NOTE: Water protection according to TSB 731-2643 edition 1 must not be mounted.

4. Assemble the MacPherson strut, in accordance with WIS - Suspension, wheels - Front suspension - Adjustment/Replacement.

5. Fit the MacPherson strut, in accordance with WIS - Suspension, wheels - Front suspension - Adjustment/Replacement.

Warranty/Time Information

In the case of customer complaint and if the car is within the warranty period, use the following information to fill out the claim:

Failed Object: 73113
Fault/Reason code: 40
Location code: 09 (US=9)
US=3 left side only, 4 right side only, 5 both sides)
Warranty Type (US): 01
Repair/Action code: 01
Labour Operation (US): 7311303 (one side) and 7311304 (both sides)
Labour Operation (CA): E3900 (one side) and E3901 (both sides)
Time: 0.7 hr one side; 1.2 hr both sides

Fault diagnosis procedure is not available.