P1802 02
P1802 02
Sentronic Circuit, Short to Ground.
Fault symptom
- No Sentronic function.
- Selector lever locked in position P or N.
On-board diagnosis
Type of diagnosis:
- Continuous
Enable criteria:
- Ignition ON.
Fault criteria:
- Control module output voltage exceeds 0.2 V.
System reaction to a fault:
- Manual shifting not permitted.
Checking the wiring harness
- Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
- Electrical fault in lead connected between SLM and TCM.
IMPORTANT: This diagnostic trouble code is also generated when the TCM's bus communication was/is faulty.
If the selector lever is moved to position M, SLM transmits a bus message. TCM is then open to up or downshifting. If the driver shifts manually, voltage is sent from pin 7 on SLM to pin 8 (A) on TCM. This is done through an analogue voltage signal sent by SLM on its own lead directly to TCM in accordance with the following:
- Hold Gear voltage between 0.5 - 1.4 V
- Shift Gear -UP, (+) voltage between 1.4 V - 1.79 V
- Shift Gear-DOWN (-) voltage between 2.7 V - 3.5 V
(These voltage levels can be measured when all contacts are engaged.)
Functions in the diagnostic tool related to the fault:
Test value:
- Selector Position Sentronic
- Selector Position Sentronic Up
- Selector Position Sentronic Down
- Shift Lever Sentronic