P1801 06
P1801 06
Shift lock-solenoid, Open/Short to Ground.
Fault symptom
- Selector lever locked in position P or N.
On-board diagnosis
Type of diagnosis:
- Continuous
Enable criteria:
- Ignition ON.
System reaction to a fault:
- Control module closes output to Shift Lock solenoid.
Checking the wiring harness
- Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
- Electrical fault in connecting leads or component.
Functions in the diagnostic tool related to the fault:
Activation:
- Shift Lock Solenoid