P0204
P0204 00
Injector 4 Circuit, Open/Short
Fault symptom
- Engine misfires or does not start.
On-board diagnosis
Type of diagnosis:
- CHECK ENGINE.
- Continuous
Enable criteria:
- Battery voltage must be between 11 - 16 V.
- Main relay voltage exceeds 6 V.
- Starter motor cranking or engine running.
Fault criteria:
- When voltage on output is below 5.5 V when inactive or exceeds 5.5 V when active.
Dependent:
- None
System reaction to a fault:
- Closed loop is blocked.
- Fuel adaption is blocked.
OK report:
- Fault criteria NOT fulfilled for 2 s.
Fault handling:
Type III
(See section Fault handling III, "Other emission-related components and functions" for more information.)
Checking the wiring harness
- Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
- Electrical fault in connecting leads or component.
Functions in the diagnostic tool related to the fault:
Activation: of output for injector 4.
(See also description of readings/activations in diagnostic tool)