B3689 01
B3689 01
6th Bow Latched Left, Position Sensor Circuit, Short to B+
Fault symptom
- Soft top cannot be operated
- Messages shown in SID.
On-board diagnosis
Type of diagnosis:
- Continuous
Enable criteria:
- Ignition ON.
Fault criteria:
- Control module input voltage exceeds 4.6 V ± 0.2 V
System reaction to a fault:
- Soft top cannot be operated
Checking the wiring harness
- Jiggle the wiring harness at several points to detect intermittent breaks or short circuits. Check also the connector for oxidation or loose pins.
Diagnostic help
Diagnosis regards:
- Electrical fault in connecting leads or component.
Functions in the diagnostic tool related to the fault:
Test value:
- 6th Bow Latched Left
(See also description of readings/activations in diagnostic tool)