B2610 02
B2610 02
Interior Light PWM Circuit, Short to Ground
Fault symptom
- Interior lighting malfunction.
On-board diagnosis
Type of diagnosis:
- Continuous
Enable criteria:
- Ignition ON.
- Interior lighting button OFF.
Fault criteria:
- When voltage on the input is below 2.0 V.
Checking the wiring harness
- Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
- Electrical fault in connecting leads or component.
Functions in the diagnostic tool related to the fault:
Test value:
- Interior Light, PWM
Activate:
- Interior Light, PWM
(See also description of readings/activations in diagnostic tool)