B1000 36 - 04
B1000 36
Control module - ECU Fault
On-board diagnosis
Type of diagnosis:
- Continuous
Enable criteria:
- Diagnostics run when ignition is ON.
Fault criteria:
- Control module on-board diagnostics has detected a EEPROM error.
Diagnostic help
- See "Before changing a control module" and "After fitting a control module" under Fault diagnosis, general.
Diagnostic help
Diagnosis regards:
- To locate electrical faults in the control module internal electronics.
Functions in the diagnostic tool related to the fault:
- See menu "All - Add/Remove"