B0448 02
B0448 02
Blower Fan Circuit, Short to Ground
Fault symptom
- Poor cabin heating
- Heater does not start.
On-board diagnosis
Type of diagnosis:
- Continuous
Enable criteria:
- Ignition ON.
- Combustion air fan active
- Heater not in rest mode.
Fault criteria:
- Combustion air fan, shorted to ground for more than 2.5 s.
System reaction to a fault:
- Heater is switched off.
Checking the wiring harness
- Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
- Electrical fault in connecting leads or component.
Functions in the diagnostic tool related to the fault:
Activate:
- Fan After Cooling
(See also description of readings/activations in diagnostic tool)