Resetting the Limp-Home Mechanism
Resetting The Limp-home Mechanism
^ Turn the ignition switch to the ON position.
^ Clear diagnostic trouble codes: Trionic.
^ Turn the ignition switch to the OFF position.
^ Wait for 10 seconds.
^ Reset the limp-home mechanism as described in the section headed 'Trionic T7 LEV/Resetting Triggered Limp-Home Solenoid'.
After performing this procedure Final Check