C0131 05
C0131 05Pressure Sensor Circuit, Open/Short to B+
Fault symptom
Warning lamp lights.
Messages shown in SID.
On-board diagnosis
Type of diagnosis:
Continuous
Enable criteria:
Ignition ON. No ABS modulation. Acceleration less than 2 m/s2 or retardation less than 2 m/s2.
Fault criteria:
When voltage on output exceeds 4.7V.
System reaction to a fault:
No ESP function
Diagnostic help
Diagnosis regards:
Electrical fault in the component.
Functions in the diagnostic tool related to the fault:
Test value:
Pedal Pressure
(See also description of readings/activations in diagnostic tool)