INFO DISPL Indicator Lamp
Indicator Lamp INFO DISPL
INFO DISPL:
Schematic:
The INFO DISPL lamp comes on when a message is shown on SID. The lamp is powered with +15 from the main instrument unit and is grounded by the main instrument unit control module. SID sends continuous bus information INFO DISPL, unit ON/OFF.
On receiving INFO DISPL ON, the control module grounds the output for the lamp which then lights up.
The main instrument unit lights this lamp for 3 seconds when the ignition is switched on.
Diagnostics
The function has no diagnostics.