Fault Conditions
P1652
Main Relay Coil Circuit. Open / Short to Ground.
Fault symptoms
- Engine will not start.
- CHECK ENGINE.
- Misfiring can occur before trouble code is generated.
On-Board Diagnostics
Type of diagnosis:
- Continuous. But interrupted when fault criteria fulfilled and will not restart until next driving cycle.
Enable criteria:
- Crankshaft rotating. Output not active.
Fault criteria:
- Output voltage below 2 V for more than 0.5 s.
Dependents:
- None.
System reaction to a fault:
- None.
OK report:
- Enable criteria fulfilled and fault criteria not fulfilled within 60 s.
Fault handling: (For more information, Fault Handling III, Other Emission-Related Components and Function)
- Type III.
Diagnostic help
Fault diagnosis concerns electrical fault in connecting leads or in the relay.
Functions in the diagnostic tool related to the fault:
- Activate main relay output.
For more information, refer to scan tool testing. Menu Read Values
Checking the wiring
Jiggle the wiring harness at several points and in different directions to detect intermittent breaks and short circuits. Observe the multimeter, diagnostic tool or test lamp during the check.
Proceed to Diagnostic Procedures Checking the Relay Power Supply