Checking the Control Module's Sensor Input
Checking The Control Module's Sensor Input
- Contact Trionic
Reading: Manifold Absolute Pressure
The reading should be 0 kPa
Checking the wiring harness.
Jiggle the leads and in-line connectors at several places and in different directions to reveal intermittent breaks and short circuits in the wiring harness. Observe the multimeter, test lamp or diagnostic tool while doing this.
Is the function correct?
NO - Rectifying the Lead - III
YES - Continue with the Checking The Control Module's Sensor Input.
- Connect a jumper lead between pins 2 and 3 of the female connector.
Reading: Manifold Absolute Pressure
The reading should be 250 kPa
Checking the wiring harness
Jiggle the leads and in-line connectors at several places and in different directions to reveal intermittent breaks and short circuits in the wiring harness. Observe the multimeter, test lamp or diagnostic tool while doing this.
Is the function correct?
NO - Rectifying the Lead - III
YES - Changing Components