Engine Control Module: Testing and Inspection
Test Readings, Control Modules Connections
Scope
The following contain readings and directions for measuring signals and levels on the Trionic Control module.
Remember
- Note the test readings, use common sense when assessing the results of the tests.
- The specified values are with the ignition in the ON position unless Otherwise stated.
- First, make sure the Control module is supplied with power and grounded.
- Then, check all the sensor inputs and signals from Other Systems.
- Finally, check the Control module outputs. Remember that the test readings do not indicate whether the actuator is working.
- If any of the test readings is incorrect, use the wiring diagram to determine which lead, connector or component should be checked further.
- The specified test values apply for a Fluke 88/97.
- The test readings % (+) and ms (+) signify the pulse ratio and pulse length of the signal respectively. A test instrument capable of measuring pulse ratio and pulse width must be used. The sign indicates a positive trigger pulse, TRIG+.