Stepping Motor, Air-Mixing RH, ACC




Stepping Motor, Air-Mixing RH

To remove








Put the air-mixing control to max cold or max heat before commencing removal.

1. Remove the glove compartment.
Remove the trim from the side of the centre console.







2. Remove the stepping motor, 2 bolts.
3. Unplug the connector.

To fit
When fitting, the lower flap must be put in the same end position as the upper flap.
Fit in reverse order.