P1132
P1132
O2S. Switch point - rich. Sensor 1
Fault symptoms
- CHECK ENGINE.
On-Board Diagnostics
Type of diagnosis:
- Continuous. Terminated when fault criteria fulfilled. Restarts next driving cycle.
Enable criteria:
- General conditions for this trouble code: Atmospheric pressure must exceed 72 kPa and the engine coolant and intake air temperature must be above -70 °C.
- Engine running. Closed loop blocked in rich or lean mode for a number of combustions in order to maintain a voltage of 0.6V from oxygen sensor 2. The number of combustions that is required is adapted.
Fault criteria:
- Closed loop blocked in lean mode for more than 35 combustions.
Dependents:
- P0115, P0116, P0117, P0118, P0119, P0131, P0132 and P0134.
System reaction to a fault:
- None.
OK report:
- Number of adapted combustions has dropped at some time during the driving cycle.
Fault handling: (For more information, Fault Handling III, Other Emission-Related Component & Function)
- Type III.
Diagnostic help
Fault diagnosis concerns an internal fault in the sensor.
Functions in the diagnostic tool related to the fault:
- Diagnostic status for the diagnosis.
For more information, Tech 2 Menu Structure, DTC Menu, Read Value, Activate, Sys Info
NOTE: Oxygen sensor receives reference oxygen from the surrounding air via the connecting cables. For this reason, electrical contact spray or grease must not be used on the oxygen sensor connector.