B2917
B2917
Right-hand centre distance sensor. Communication cable, open-circuit/shorted to ground
Fault symptoms
- Error message "PARKING ASSIST FAILURE" shown on the SID when reverse is selected.
- The SPA stops measurement and acoustic signals are given by the SID when the SPA shuts down.
Condition
The following conditions apply for the diagnostic trouble code in question:
- Ignition switch in ON position
- Reverse gear selected
Diagnostic help
This fault diagnosis concerns electrical faults in the connection cables or distance sensor.
Diagnostic tool functions related to the fault:
- Right-hand centre distance sensor, distance to object in cm.
For further information about readings, see Menu "Read Values". Tech 2 Menu Structure, Read Values