B2345





Mixed-air sensor Right. Short to ground
Mixed-air sensor Right. Open circuit/short to B+

Fault symptoms

Perceived temperature in cabin too high or too low compared to the set temperature.

Conditions
The following conditions apply:
- Open circuit or short to B+ on pin 18 >4.9 V.
- Short to ground on pin 18<0.1 V.
- Measured every 440 ms and 5 consecutive measurements are required to set a diagnostic trouble code.
- The diagnostic trouble code is deleted after the ignition has been switched on 20 times if the fault conditions have not been fulfilled.
- When the diagnostic trouble code is set, the control module uses the default value, which is the relative opening of the air-mixing flap in question multiplied by the coolant temperature.