EVAP Canister Purge Valve (321)
To remove
1 Undo the quick-coupling on the hose with the clamp.
2 Detach the rubber valve holder from the mounting.
3 Carefully rotate the valve and unplug the connector.
4 Detach the valve from the hose.
To fit
NOTE: Spray the connector with kontakt 61 (part no.30 04 520).
1 Connect the purge valve to the connecting hose.
2 Plug in the purge valve connector.
3 Fit the purge valve to the bracket.
4 Connect the quick-release coupling on the purge hose to the evaporative emission canister.