Conditions
B2375
Heat exchanger solenoid. Short to B+
Heat exchanger solenoid. Open circuit/short to ground
Fault symptoms
The perceived cabin temperature is too high or too low compared to the set temperature.
Conditions
The following conditions apply:
- A short to B+ is indicated when the output for the heat exchanger solenoid is activated and the voltage on pin 24 exceeds 6 V.
- A short to ground is indicated when the output for the circulation pump is not activated and the voltage on pin 24 exceeds 6 V.
- Measured every 440 ms and 5 consecutive measurements are required to set a diagnostic trouble code.
- The diagnostic trouble code is deleted after the ignition has been turned on 20 times if the fault conditions have not been fulfilled.
- When the diagnostic trouble code has been set the output is switched off.