Checking Compressor Engagement
Checking Compressor Engagement
Start the engine and run it at idling speed.
^ Turn on air recirculation, select maximum heat for both zones and set the fan to maximum speed.
^ Close all the doors and windows. Wait for five minutes.
The compressor should run continuously.
Is the function correct?
NO ^ Checking Conditions For Engagement
YES ^ Checking Evaporator Temperature In DICE - I