Absolute Pressure Sensor: Service and Repair
To remove
1. Unplug the ignition discharge module 10-pin connector and bend it to one side.
2. Unplug the sensor connector.
3. Undo the connector.
To fit
1. Check the sealing washer and fit a new one if necessary.
Apply Vaseline (part no.30 04 520) or equivalent to the sensor threads. Fit the sensor
Tightening torque 17 Nm (12 lbf ft)
2. Spray the connector with Kontakt 61 (pant no.30 04 520). Plug in the connector.
3. Plug in the ignition discharge module 10-pin connector.