Accelerator Pedal: Service and Repair
Accelerator
To Remove
1 Open the data link connector cover.
2 Remove the 2 screws from the data link connector.
3 Remove the 3 bolts securing the lower panel with air duct.
4 Unplug the connector for the floor lighting.
5 Lift out the lower panel.
6 Disconnect the throttle cable from the accelerator by sliding back the bush and removing it and the cable.
7 Remove the pedal (2 nuts).
To fit
NOTE: Spray the connector with kontakt 61, part no. 30 04 520.
Fit in reverse order.