Trionic T7 V6
To remove
IMPORTANT
The cables must not be twisted. Twisted cables exposed to vibration can break. The oxygen sensor is sensitive to impacts and jolting and must be handled with car
1 Unplug the oxygen sensor connector.
2 Raise the car.
3 Cut off the cable tie securing the oxygen sensor cable. Note how the cables are positioned and lower the cable. Remove the oxygen sensor.
To fit
IMPORTANT
The cables must not be twisted. Twisted cables exposed to vibration can break.
The oxygen sensor is sensitive to impacts and jolting and must be handled with care.
NOTE: Coat the oxygen sensor threads sparingly with Molykote 1000 (part no.30 20 971).
1 Fit the oxygen sensor.
Tightening torque: 55 Nm (40.5 lbf ft).
2 Carefully replace the cable to the oxygen sensor connector. Secure the cable with a cable hhhhh
3 Lower the car and plug in the oxygen sensor connector.