EVAP Canister Purge Valve (321)
To remove
1 Release the snap-on coupling on the purge hose to the evap canister with tool no.83 95 261. Press down the brace.
2 Remove the evap canister purge valve from the bracket.
3 Carefully twist the evap canister purge valve and unplug the connector.
4 Loosen the evap canister purge valve from the connecting hose.
To fit
NOTE: Spray the connector with Kontakt 61 contact cleaner (part no.30 04 520).
1 Connect the evap canister purge valve to the connecting hose.
2 Plug in the evap canister purge valve connector.
3 Fit the evap canister purge valve to the bracket.
4 Fit the snap-on coupling on the purge hose to the evap canister.