Trionic T7
To remove
1 Unplug the 10-pin ignition discharge module connector.
2 Remove the 4 ignition discharge module screws.
3 Remove the spark plugs.
To fit
1 Apply Molykote 1000 (part no.30 20 971) or equivalent to the spark plug threads.
2 Apply Krytox (part no.30 19 312) to the rubber seals.
3 Fit the spark plugs and check the gap.
Tightening torque 28 Nm (21 lbf ft)
4 Fit the 4 ignition discharge module screws.
Tightening torque 11 Nm (8.1 lbf ft)
5 Plug in the 10-pin ignition discharge module connector.