Main Beam Indicator Lamp
Main Beam Indicator Lamp:
Fault symptoms
The main beam indicator lamp is inoperative.
Diagnostic help
The lamp is grounded in the main instrument unit and supplied with current from main beam fuse 8.
Check the Wiring harness
Jiggle the wiring harness at several points and in different directions to detect intermittent breaks and short-circuits in the leads. Observe the multimeter, test lamp or diagnostic tool during the test.