FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Power Seats Cannot be Operated When Rear Door Is Opened









Fault symptoms
The seat cannot be operated when the driver's door is open and the ignition is off.

Probable cause of fault
Faulty door contact or faulty lead from door contact to TWICE.

Check the wiring
Jiggle the wiring harness in several places and in various directions to detect intermittent open circuits and short circuits in the wiring harness. Watch the multimeter, diagnostic tool and test lamp during the check.

Power Seat Cannot Be Operated When Passenger Door Is Opened







Fault symptoms
The seat cannot be operated when the front passenger door is open and the ignition is off.

Probable cause of fault
Faulty door contact or faulty lead from door contact to TWICE.

Check the wiring
Jiggle the wiring harness in several places and in various directions to detect intermittent open circuits and short circuits in the wiring harness. Watch the multimeter, diagnostic tool and test lamp during the check.

Power Seat Cannot Be Operated When Rear Left Door Is Opened







Fault symptoms
The seat cannot be operated when the left rear door is open and the ignition is off.

Probable cause of fault
Faulty door contact or faulty lead from door contact to TWICE.

Check the wiring
Jiggle the wiring harness in several places and in various directions to detect intermittent open circuits and short circuits in the wiring harness. Watch the multimeter, diagnostic tool and test lamp during the check.

Power Seat Cannot Be Operated When Right Rear Door Is Opened







Fault symptoms
The seat cannot be operated when the right rear door is open and the ignition is off.

Probable cause of fault
Faulty door contact or faulty lead from door contact to TWICE.

Check the wiring
Jiggle the wiring harness in several places and in various directions to detect intermittent open circuits and short circuits in the wiring harness. Watch the multimeter diagnostic tool and test lamp during the check.