FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Mechanical Specifications

knock sensor
voltage voltage tightening torque
approx. 5 Millivolts Alternating Current (mVAC)
Note: Voltage at idling speed. The voltages are measured directly on the sensor connections. The knock sensor pins are gold plated.
approx. 100 Millivolts Alternating Current (mVAC)
Note: Voltage when mounting frome tapped with hammer. The voltages are measured directly on the sensor connections. The knock sensor pins are gold plated.
22 Newton Meter (Nm)