FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Power Supply (+X Circuit)

Power Supply (+X Circuit):




WIRING DIAGRAM

DESCRIPTION OF OPERATION
Positive current is supplied from the battery to the ignition switch via Maxi fuse 3.

When the ignition switch is in the Park, Drive or Start position, terminals 30 and X on the ignition switch are connected to each other.

Current (+X circuit) is then supplied to:
^ Main fuse board 22A
- Fuse 9
^ Lights switch 10

FAULT DIAGNOSIS HINTS
1. Check the battery voltage.
2. Check that current is supplied to fuse 9 and lights switch 10.
3. Check the relevant wiring harness.