Power Supply (+30 Circuit)
Positive voltage is taken directly from battery 1 to the following components:^ Starter motor 4 and then generator 2
^ Maxi fuse holder 501
- maxi fuses 1-5
Positive voltage is taken from the battery and supplied via crimped connection J3 to the following components:
^ Main fuse board 342A
-fuses 1-3, 5, 12
-maxi fuses 1-3
^ Lighting relay 8
^ Main and dipped beam relay 8A
Current is supplied to the following components via maxi fuse 1 in max fuse holder 501 and crimped connection J89:
^ Main fuse board 22A
- Fuses 1, 4, 11, 13, 23, 25, 26 and 34
Current is supplied to the following components via max fuse 2 in maxi fuse holder 2 and crimped connection J2:
^ Main fuse board 22A
- Fuses 2, 5, 10, 12, 16, 27, 28, 35
^ Starter relay 517
^ Lights switch 10
^ Fuel pump relay 102
^ Fuel injection relay 229
Current is supplied to the following component via Maxi fuse 3:
^ Ignition switch 20
Current is supplied to the following component via Maxi fuse 4:
^ Ignition switch relay 21