Trip Computer
COMMUNICATION FAULT WITH SENSONIC
Conditions
B1471 Generated in the event of incorrect data or no data from the Sensonic for more than 5 seconds.
B1473 Communication lead between the SID and Sensonic shorted to ground.
Fault Symptoms
Messages from the Sensonic not displayed on the SID.
Important: Diagnostic trouble code B1471 could be a consequential fault of B1473.
Diagnostic Procedure
1 Connect a ISAT Scan Tool.
- Select "SAAB INFO DISPLAY".
- Select "READ VALUES".
- Select "DATA FROM ACS".
2 Simulate a message.
- Engage a high gear, for example, and turn the ignition switch to the ON position. This should generate the "DISENGAGE GEAR" message on the SID and ISAT Scan Tool.
- If no message appears on either the SID or ISAT Scan Tool, see point 3.
- If the message does appear, the fault is intermittent. See point 4.
3 Wiring harness check.
- Check the wiring between pin 6 of the SID unit and pin 24 of the Sensonic control module for continuity and/or shorting to ground.
- If the wiring harness is intact, change the Sensonic control module.
4 Connector check.
- Check the connectors for slide-out and corrosion.