Trip Computer
COMMUNICATION FAULT WITH ICE, SHORTED TO GROUND
Fault Symptoms
One or more of the following:
- The "REAR LIGHTS U/S" message does not work.
- The "BRAKE LIGHTS U/S" message does not work.
- The "TEST BRAKE LIGHTS" message does not work.
- The acoustic reminder does not work.
- The direction indicator acoustic repeater does not work.
Diagnostic Procedure
1 Check the wiring by connecting a BOB to the 22-pin connector behind the SID unit (SID unit disconnected). Unplug the 70-pin ICE connector.
2 Check for shorting to ground between pin 8 of the SID unit and pin 37 of the ICE. Locate and rectify the fault.