Refrigerant Pressure Sensor / Switch: Service and Repair
Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement
Removal Procedure
1. Discharge and recover the refrigerant. Refer to Refrigerant Recovery and Recharging (Refrigerant Recovery and Recharging).
2. Disconnect the A/C refrigerant pressure switch electrical connector (1).
3. Remove the A/C refrigerant pressure switch (2). Use a second wrench to hold the switch mount to avoid bending the liquid line.
Installation Procedure
Caution: Refer to Fastener Caution (Fastener Caution).
Note:
* Use new O-rings lubricated with 525 viscosity mineral oil.
* Hold the A/C refrigerant pressure switch mount with an open end wrench to avoid bending the liquid line.
1. Install the A/C refrigerant pressure switch (2).
Tighten the A/C refrigerant pressure switch (2) to 11 Nm (8.0 lb ft).
2. Connect the A/C refrigerant pressure switch electrical connector (1).
3. Evacuate and recharge the refrigerant system. Refer to Refrigerant Recovery and Recharging (Refrigerant Recovery and Recharging).
4. Operate the A/C system and check for leaks. Refer to Leak Testing (Leak Testing).