Compressor Pressure Relief Valve Installation
Compressor Pressure Relief Valve Installation
1. Clean the pressure relief valve seat area on the A/C compressor.
2. Lubricate the O-ring of the new pressure relief valve with clean refrigerant oil.
Caution: Refer to Fastener Caution (Fastener Caution).
3. Install the new pressure relief valve (1) into the A/C compressor.
Tighten the pressure relief valve to 7 Nm (60 lb in).