Air Cleaner Fresh Air Duct/Hose: Service and Repair
AIR CLEANER INTAKE DUCT REPLACEMENT
REMOVAL PROCEDURE
1. Turn OFF the ignition.
2. Disconnect the electrical connector from the intake air temperature (IAT) sensor.
3. Disconnect the breather tube from the air cleaner intake duct.
4. Loosen the clamps securing the air cleaner intake duct.
5. Remove air cleaner intake duct.
INSTALLATION PROCEDURE
1. Install the air cleaner intake duct.
IMPORTANT: An improperly installed air cleaner intake duct or breather tube will cause incorrect sensor readings resulting in MIL illumination or a drivability concern.
2. Tighten the clamps securing the air cleaner intake duct.
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten the clamp to 3 N.m (27 lb in).
3. Connect the breather tube to the air cleaner intake duct.
4. Connect the electrical connector to the IAT sensor.