Sunroof / Moonroof: Description and Operation
CIRCUIT OPERATIONPower Sunroof
Power for the tilt and slide switches is supplied on circuit F10. This circuit is HOT in the ACCESSORY and RUN position only, and protected by a 20 Amp fuse located in the fuse block, cavity 14.
Power for the fuse is supplied by circuit A31. This circuit connects from the ignition switch to the fuse block.
Feed for the A31 circuit is supplied on circuit A1. This circuit is protected by a 30 Amp fuse located in the Power Distribution Center (PDC).
Sunroof Open/Close
When the operator selects sunroof OPEN the switch connects the feed circuit F10 to circuit Q41. The Q41 circuit connects from the switch to the OPEN side of the motor.
Ground for the motor is supplied on circuit Q42 from the motor back to the CLOSE side of the open/close switch. The ground is passed through the bus bar in the switch to circuit Q45. Circuit Q45 connects from the open/close switch to the tilt switch.
The ground is passed through the switch to circuit Z8 and finally to ground.
When the operator selects the CLOSE function, power and ground are reversed.
Tilt Open/Close
When the operator selects tilt OPEN circuit F10 is connected to circuit Q43. Circuit Q43 connects from the switch to the CLOSED vent limit switch in the sunroof module.
The voltage is passed through the switch to circuit Q46 The Q46 circuit connects from the limit switch to the slide switch OPEN side.
Power is passed through the switch to the Q41 circuit, then to the power sunroof motor.
Ground is provided on circuit Q42 from the motor to the slide switch CLOSE side. The ground is passed through the bus bar in the switch to circuit Q45. The Q45 circuit connects from the slide switch to the tilt switch CLOSE side.
Ground is passed through the switch to the Z8 circuit and to ground.
When the operator selects the VENT CLOSE function, power and ground are reversed.