P0150

CIRCUIT DESCRIPTION
Heated oxygen sensors (HO2S) are used for fuel control and post catalyst monitoring. Each HO2S compares the oxygen content of the surrounding air with the oxygen content of the exhaust stream. When the vehicle is first started, the powertrain control module (PCM) operates in an Open Loop mode, ignoring the HO2S signal voltage when calculating the air-to-fuel ratio. The PCM supplies the HO2S with a reference, or bias, voltage of about 450 mV. The HO2S generates a voltage within a range of 0-1,000 mV that fluctuates above and below bias voltage once in Closed Loop. A high HO2S voltage output indicates a rich fuel mixture. A low HO2S voltage output indicates a lean mixture. Heating elements inside the HO2S minimize the time required for the sensors to reach operating temperature, and to provide an accurate voltage signal. If the PCM detects an active HO2S 1 signal of a lower than calibrated minimum amplitude, DTC P0130 or P0150 will set.

CONDITIONS FOR RUNNING THE DTC
- DTCs P0101, P0102, P0103, P0106, P0107, P0108, P0116, P0117, P0118, P0121, P0122, P0123, P0125, P0128, P0131, P0132, P0133, P0134, P0151, P0152, P0153, P0154, P0201-P0208, P1133, P1134, P1153, P1154 are not set.
- The system voltage is between 10-18 volts.
- The ECT Sensor parameter is more than 68°C (154°F).
- The Engine Run Time parameter is more than 120 seconds.
- The Engine Speed parameter is between 500-5,000 RPM.
- The MAF Sensor parameter is between 3-30 g/s.
- The Loop Status parameter is closed.
- All of the above conditions are met for 5 seconds.

CONDITIONS FOR SETTING THE DTC
The PCM detects that the affected HO2S 1 voltage is between 350-500 mV for more than 16 seconds, during a 120 second monitoring period.

ACTION TAKEN WHEN THE DTC SETS
- The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails.
- The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records.

CONDITIONS FOR CLEARING THE MIL/DTC
- The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail.
- A current DTC, Last Test Failed, clears when the diagnostic runs and passes.
- A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic.
- Clear the MIL and the DTC with a scan tool.

TEST

Steps 1-3:




Steps 4-7:




Step 8:




Steps 9-14: