A/C Refrigerant Pressure Sensor Replacement
A/C Compressor Hose:
REMOVAL PROCEDURE
IMPORTANT: The pressure sensor is mounted on a Schrader-type valve. Do not recover the refrigerant from the A/C system when replacing this sensor.
1. Disconnect the electrical connection from the sensor.
2. Remove the following components:
^ The switch
^ The O-ring seal
INSTALLATION PROCEDURE
1. Lubricate the O-ring using 525 refrigerant oil.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the following components:
^ The new O-ring seal
^ The switch
Tighten
Tighten the sensor to 12 N.m (9 lb ft).
3. Connect the electrical connection to the switch.