A/C Refrigerant Pressure Sensor
Removal Procedure1. Remove the air cleaner and duct assembly.
2. Disconnect the battery negative cable.
3. Disconnect the electrical connector from the A/C refrigerant pressure sensor.
4. Remove the refrigerant pressure sensor from the liquid line.
Installation Procedure
Important: Lubricate a new O-ring seal with mineral base 525 viscosity refrigerant oil.
1. Install the new O-ring seal.
2. Install the refrigerant pressure sensor to the liquid line.
Tighten
Tighten the sensor to 4.7 N.m (41 lb in).
3. Connect the electrical connector to the A/C refrigerant pressure sensor.
4. Connect the battery negative cable.
5. Install the air cleaner and duct assembly.