Pivot & Pulse Switch Assembly - Floor Shift
Part 1 Of 2:
Part 2 Of 2:
REMOVE OR DISCONNECT
1. Negative (-) battery cable.
2. Do steps 1 through 4 under REMOVE OR DISCONNECT in UPPER COVER LOWER COVER.
3. Two wire straps (31) from steering column wire harness.
4. Pivot & pulse switch assembly (16) connector from turn signal & multifunction switch (32) wire harness connector.
5. Pivot & pulse switch (16) harness from wire harness strap (57).
6. Two tapping screws (26).
7. Pivot & pulse switch assembly (16) from column.
INSTALL OR CONNECT
NOTICE: Always use the correct fastener in the proper location. When you replace a fastener, use ONLY the exact part number for that application. The manufacturer will call out those fasteners that require a replacement after removal. The manufacturer will also call out the fasteners that require thread lockers or thread sealant. UNLESS OTHERWISE SPECIFIED, do not use supplemental coatings (paints, greases, or other corrosion inhibitors) on threaded fasteners or fastener joint interfaces. Generally, such coatings adversely affect the fastener torque and joint clamping force, and may damage the fastener. When you install fasteners, use the correct tightening sequence and specifications. Following these instructions can help you avoid damage to parts and systems. Failure to do so may result in component damage or malfunction of steering column.
1. Pivot & pulse switch assembly (16) to column.
2. Two tapping screws (26).
Tighten
Tighten screws (26) to 2.5 Nm (22 lb in).
3. Pivot & pulse switch (16) harness to wire harness strap (57).
4. Pivot & pulse switch (16) connector to turn signal & multifunction switch (32) wire harness connector.
5. Two wire straps (31) to steering column wire harness.
6. Do steps 8 through 10 under INSTALL OR CONNECT in UPPER COVER LOWER COVER.
7. Negative (-) battery cable.