Test B False Alarm Test
^ If false alarm shuts off after 2 to 4 minutes, check for: Stuck or intermittent Door Latch or Door Lock Assembly Switch Stuck or intermittent Tamper Switch- Ground or intermittent ground in wiring associated with those switches
^ If false alarm is continuous or intermittent for more than 2 to 4 minutes, check for:
- Ground or intermittent ground in wiring to Remote Accessory Control (RAC) Module Connector C3 terminal H for horns, or RAC Module Connector C3 terminal H for exterior lamps
- Defective RAC Module. If alarm stops when RAC Module is disconnected, replace RAC module (refer to Programming Procedure in Keyless Entry). Keyless Entry
^ Repeat System Check