Removal and Installation
EVAPORATIVE EMISSION SYSTEM
Removal and Installation
EVAP CANISTER
Removal
1.Remove EVAP canister protector.
2.Disconnect the EVAP canister control pressure sensor electrical connector.
3.Remove the EVAP canister control pressure sensor and O-ring, if necessary.
CAUTION:
Discard the O-ring. Do not reuse O-ring.
4.Disconnect EVAP canister purge hose.
5.Remove the EVAP canister retaining bolt.
6.Disconnect fuel tank EVAP breather hose.
7.Disconnect EVAP vent control valve connector.
8.Disconnect the EVAP vent control valve hose.
9.Remove the EVAP canister.
10.Remove the EVAP vent control valve and O-ring, if necessary.
CAUTION:
Discard the O-ring. Do not reuse O-ring.
Installation
Installation is in the reverse order of removal.
CAUTION:
Do not reuse O-ring.
EVAP CANISTER CONTROL PRESSURE SENSOR
Removal
1.Remove EVAP canister protector.
2.Disconnect the EVAP control pressure sensor connector.
3.Remove the EVAP canister control pressure sensor and O-ring.
CAUTION:
Discard the O-ring. Do not reuse O-ring.
Installation
Installation is in the reverse order of removal.
CAUTION:
Do not reuse O-ring.
EVAP CANISTER VENT CONTROL VALVE
Removal
1.Remove EVAP canister protector.
2.Disconnect EVAP vent control valve connector.
3.Disconnect the EVAP vent control valve hose.
4.Turn EVAP canister vent control valve counterclockwise.
5.Remove the EVAP canister vent control valve and O-ring.
CAUTION:
Discard the O-ring. Do not reuse O-ring.
Installation
Installation is in the reverse order of removal.
CAUTION:
Do not reuse O-ring.
EVAP CANISTER FILTER
Removal
1.Disconnect the EVAP canister filter drain hose.
2.Disconnect the EVAP hose.
3.Remove the EVAP canister filter.
Installation
Installation is in the reverse order of removal.