Air Breather Hose
AIR BREATHER HOSE
Removal and Installation (MR20DE)
REMOVAL
1.Disconnect the clip from the resonator.
2.Remove the air breather hose from the air breather tube.
INSTALLATION
Installation is in the reverse order of removal.
CAUTION:
Make sure air breather hose is not collapsed or blocked due to folding or bending when installed.
NOTE:
- Install the air breather hose (3) to the air breather tube (4) so that the paint mark (A) faces upward. Also make sure the air breather hose end is pushed up to the air breather tube bend position.
- When installing air breather hose (3) to the resonator (1) make sure to fully insert the clip (2).