Hazard Reminder Operation Does Not Operate
HAZARD REMINDER OPERATION DOES NOT OPERATE
Diagnosis Procedure
1. CHECK DTC WITH BCM AND COMBINATION METER
Check that DTC is not detected with BCM and combination meter.
Is the inspection result normal?
YES- GO TO 2.
NO-1- Testing and Inspection. (BCM)
NO-2- Testing and Inspection. (Combination meter)
2. CHECK "HAZARD LAMP SET" SETTING IN "WORK SUPPORT"
1.Select "MULTI REMOTE ENT" of "BCM" using CONSULT.
2.Select "HAZARD LAMP SET" in "WORK SUPPORT" mode.
3.Check "HAZARD LAMP SET" in "WORK SUPPORT".
Door & Lock.
Is the inspection result normal?
YES- GO TO 3.
NO- Set "HAZARD LAMP SET" in "WORK SUPPORT".
3. CHECK HAZARD WARNING LAMP
Check hazard warning lamp.
Without Intelligent Key System.
Is the inspection result normal?
YES- GO TO 4.
NO- Repair or replace the malfunctioning parts.
4. REPLACE BCM
1.Replace BCM. Service and Repair.
2.Confirm the operation after replacement.
Is the result normal?
YES- INSPECTION END
NO- Check intermittent incident. Intermittent Incident.