Insufficient Heating
INSUFFICIENT HEATING
Description
- Insufficient heating
- No warm air comes out. (Air flow volume is normal.)
Diagnosis Procedure
NOTE:
Perform self-diagnosis with CONSULT before performing symptom diagnosis. If any malfunction result or DTC
is detected, perform the corresponding diagnosis.
1. CHECK COOLING SYSTEM
1.Check engine coolant level and check for leakage. Inspection.
2.Check radiator cap. Service and Repair.
3.Check water flow sounds of the engine coolant. Refilling Engine Coolant.
Is the inspection result normal?
YES- GO TO 2.
NO- Refill engine coolant and repair or replace parts depending on the inspection results.
2. CHECK HEATER HOSE
Check installation of heater hose by visually or touching.
Is the inspection result normal?
YES- GO TO 3.
NO- Repair or replace parts depending on the inspection results.
3. CHECK HEATER CORE
1.Check temperature of inlet hose and outlet hose of heater core.
2.Check that inlet side of heater core is hot and the outlet side is slightly lower than/almost equal to the inlet side.
CAUTION:
Always perform the temperature inspection in a short period of time because the engine coolant temperature is very hot.
Is the inspection result normal?
YES- GO TO 4.
NO- Replace heater core. Service and Repair.
4. CHECK AIR LEAKAGE FROM EACH DUCT
Check duct and nozzle, etc. of air conditioning system for air leakage.
Is the inspection result normal?
YES- Check air mix door cable installation and air mix door operation.
NO- Repair or replace parts depending on the inspection results.