Temperature Setting Trimmer
AUXILIARY MECHANISM
Temperature Setting Trimmer
DESCRIPTION
If the temperature felt by the customer is different than the air flow temperature controlled by the temperature setting, the A/C auto amp. control temperature can be adjusted to compensate for the temperature setting.
OPERATING PROCEDURES
1.Begin self-diagnosis STEP 5 mode. Reading and Clearing Diagnostic Trouble Codes.
2.Press fan control switch (up: +) to enter the set temperature setting trimmer mode from STEP 5, and then display shows "0�
C (0�F)".
3.The indication temperature will be changed by 1�C (1�F) in range of 3�C (-6�F) to +3�C (+6�F) by pressing the temperature control switch each time.
USA models
Canada models
NOTE:
- When 3�C (-6�F) is corrected on the temperature setting set as 25�C (75�F), the temperature controlled by
A/C auto amp. is 25�C (75�F) 3�C (6�F) = 22.0�C (69�F) and the temperature becomes lower than the temperature setting.
- When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10
V or less, the setting of the difference between the set temperature and control temperature may be cancelled.