FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

RH




ROCKER COVER

Removal and Installation RH


REMOVAL

1.Remove the engine room cover.
2.Remove the intake manifold collector. Intake Manifold Collector.
3.Remove ignition coils. RH.

CAUTION:
Never shock ignition coils.





4.Remove camshaft position sensor.

CAUTION:
- Handle carefully to avoid dropping and shocks.
- Do not disassemble.
- Do not allow metal powder to adhere to magnetic part at sensor tip (A).
- Do not place sensors in a location where they are exposed to magnetism.





5.Remove RH rocker cover bolts from cylinder head as shown.





INSTALLATION

Installation is in the reverse order of removal.





- Apply sealant to the areas on the front corners using Tool.
- Use Genuine Silicone RTV Sealant or equivalent. Recommended Chemical Products And Sealants.
Tool number: WS39930000 (-)

CAUTION:
The components must be installed within 5 minutes of the liquid gasket application. Then allow 30 minutes for the liquid gasket to set before operating the engine.
- Tighten the rocker cover bolts in two steps in the order as shown.