RH
ROCKER COVER
Removal and Installation RH
REMOVAL
1.Remove the engine room cover.
2.Remove the intake manifold collector. Intake Manifold Collector.
3.Remove ignition coils. RH.
CAUTION:
Never shock ignition coils.
4.Remove camshaft position sensor.
CAUTION:
- Handle carefully to avoid dropping and shocks.
- Do not disassemble.
- Do not allow metal powder to adhere to magnetic part at sensor tip (A).
- Do not place sensors in a location where they are exposed to magnetism.
5.Remove RH rocker cover bolts from cylinder head as shown.
INSTALLATION
Installation is in the reverse order of removal.
- Apply sealant to the areas on the front corners using Tool.
- Use Genuine Silicone RTV Sealant or equivalent. Recommended Chemical Products And Sealants.
Tool number: WS39930000 (-)
CAUTION:
The components must be installed within 5 minutes of the liquid gasket application. Then allow 30 minutes for the liquid gasket to set before operating the engine.
- Tighten the rocker cover bolts in two steps in the order as shown.